Description
UL Type 1, 4, 4X & IP66 protection
Waterproof membrane
Easy to install
Two sizes – M40 & M12
Pressure differentials in a hermetically sealed enclosure are a result of the heat generated by electrical and electronic components in the enclosure, as well as the fluctuation of the outside temperature. In the case of negative pressure or vacuum, for example, dust and humidity can enter the enclosure trough the door seal. The DA 284 Vent Plug provides a protected enclosure environment for valuable and crucial components with a UL 4X rated degree of protection. A waterproof membrane inside the device allows air and humidity to leave the enclosure while not allowing moisture and dust from the outside to enter.
UL Type 1, 4, 4X & IP66 protection
Waterproof membrane
Easy to install
Two sizes – M40 & M12
UL Type 1, 4, 4X & IP66 protection
Waterproof membrane
Easy to install
Two sizes - M40 & M12
Mounting: | thread with nut (see below) |
Torque: | 5 Nm (max. 10 Nm) |
Sealing: | NBR gasket |
Material: | plastic, UL 94V-0, light grey weather proof and UV light resistant according to UL746(f1) |
Filter: | waterproof membrane |
Agency approvals: | UL File No. E234324 |
Operating / Storage temperature: | -31 to +158 °F (-35 to 70 °C) |
Environmental rating: | Type 1, 4 and 4X |
Datasheet |
|